Home / Energy efficiency

D2 · Energy efficiency

Control and optimise your energy consumption.

Energy audit and diagnosis, ISO 50001 energy management system, IPMVP regression analysis: savings identified, measured and verified over time.

Self-qualification

You are concerned if…

  • You exceed 1,500 toe/year in industry or 500 toe/year in the tertiary sector — mandatory audit
  • Your five-yearly regulatory audit is due, or was never declared to AMEE
  • You are targeting ISO 50001 certification or need to maintain it
  • You need to prove to a lender the savings actually achieved after works
Activities covered

Two activities, one anchor and one block per activity

1

Energy audit & diagnosis

Regulatory or voluntary audit: on-site measurement campaign, electrical and thermal flow balance, review of utilities — steam, compressed air, cooling, HVAC, motors — quantified savings potential prioritised by payback time, and declaration to AMEE.

Flagship deliverable
Audit report + energy balance + AMEE declaration
Standard
Law 47-09, decree 2-17-746, ISO 50002, EN 16247-1 to -4
2

EnMS ISO 50001

Support from gap diagnosis through to certification audit: energy review, baseline and performance indicators, documentation system, measurement plan, verification of savings under the IPMVP protocol, and adoption by teams.

Flagship deliverable
EnMS manual + costed action plan + verified savings reports
Standard
ISO 50001:2018, ISO 50004, ISO 50006, IPMVP
What you receive

Delivered objects, not billed hours

  • Audit report, energy balance and AMEE declaration
  • EnMS manual and costed action plan
  • Savings reports verified under the IPMVP protocol
Electrical switchgear and supervision equipment in an industrial technical room
Illustration — supervision switchgear in a technical room, the spirit of continuous energy monitoring.
Sector context

Managing your energy performance

An ISO 50001 energy management system runs on the same reflex as an industrial control room: measure continuously, compare against a baseline, and act before drift sets in. Department D2 structures this discipline, from audit through to verified savings.

Illustration — steam boilers in a plant room, a utility item typically covered by an audit.
Industrial utilities

The gains hide in the utilities, not the product

Steam, compressed air, industrial cooling, building management systems: these utility items often hold the first pool of savings, ahead of the production process itself. The energy audit ranks them and prices the payback time of each action.

Standards applied

The body of standards that makes the deliverable defensible

  • Law 47-09 and decree 2-17-746 — mandatory energy audit
  • ISO 50002, EN 16247-1 to -4 — energy audit method
  • ISO 50001:2018, ISO 50004, ISO 50006 — energy management system
  • IPMVP — measurement and verification of savings protocol
Method

How a mission unfolds

1

Qualification & scoping

Scoping of the perimeter, issues and expected deliverables.

2

Collection & calculation

Measurement campaign, data collection, flow balance.

3

Technical exit review

Review by Doctrine & Methods before delivery.

4

Delivery & handover

Audit report, AMEE declaration or EnMS manual handed to the client.

5

Mission extension

Savings follow-up, five-yearly renewal, certification.

Illustration

An anonymised case

Illustrative example — no named reference
Context
An agri-food site above the 1,500 toe/year threshold, with an overdue five-yearly regulatory audit.
Scope
Measurement campaign on the steam and compressed air utilities, AMEE declaration.
Result
Savings potential prioritised by payback time and declaration regularised — illustrative order of magnitude, not audited.
Who leads this expertise

D2 lead — position filled, AMEE signatory

A detailed profile (education, certifications, years of practice) will be published by Management in wave 2, in line with the go-live roadmap.

Qualification

Check whether the mandatory audit applies to me

This form sends your request directly to contact@morweis.com, assigned to department D2.

Thresholds: 1,500 toe/year in industry, 500 toe/year in the tertiary sector.

Your request is sent directly to contact@morweis.com — response targeted within 5 business days.